LODD Capt. Jeff Bowen
Share
Copy
Download
0
909
Published on Nov 20, 2015
No Description
View Outline
MORE DECKS TO EXPLORE
PRESENTATION OUTLINE
1.
CAPTAIN JEFFERY BOWEN
8/11/73 - 7/28/11
Asheville Fire Department
2.
ABOUT FIREFIGHTER BOWEN
Native of San Bernardino, CA
Lived in Alexander, NC
Wife - Stacy Cutshall Bowen
Children - Robin Parker, Sarah & Charlie Ray Bowen
Grandchildren - Emma Parker
3.
EDUCATION, COMMUNITY & HOBBIES
13 Year Veteran for AFD
2010 Bachelor's degree in Fire Safety & Management
Coordinated Rescue Boat for APD Back to the Basics
Member of AFD Promotional Criteria Committee
Avid Bowhunter
4.
ASHEVILLE FIRE DEPARTMENT
12 Stations
11 Engines, 4 Trucks, 1 Rescue, 1 Tender
237 Uniformed Members
24/48 and 24/96 Hour Shifts
Serves 83,000 Residents with Daytime Pop. of 150,000
5.
THE INCIDENT
445 BILTMORE AVENUE, ASHEVILLE, NC
6.
FIRE KEY POINTS
Location - 5th Floor A/B Corner of Medical Office Building
Arson Fire
First Four Alarm Fire In Over 30 Years
Over 60 Responded & 9 Other Firefighters Injured
First LODD in Asheville since 1982
7.
RADIO RECORDING
OF MAYDAY CALL
http://youtu.be/bY9I33DG2Zo
8.
INTERIOR EVENTS
Engine 2 connected 100ft. of 2.5in. to standpipe
E2 flowed water for several minutes before exiting due to low air
Rescue 3 headed up North stairwell and got on original hose line
Other crews had brought up additional high-rise packs
When additional packs were charged, multiple kinks created
9.
Untitled Slide
10.
INTERIOR EVENTS CONT.
R3 reported no water on hose line
Two of R3's crew were low on air so crew moved to stairwell
The two FF's exited but the captain (victim) continued down hallway
Other two FF's went after victim, afterward all three were low on air
Victim was confused and they headed back to stairwell
11.
INTERIOR EVENTS CONT.
One FF got separated but found exit at window with ladder
Victim ran out of air and asked partner to buddy breath
Victims disconnected regulator as parter attached buddy breather
All of the air then escaped victims face piece
Victim then finally transmitted Mayday and activated PASS
12.
INTERIOR EVENTS
FF also attempted to activate PASS and transmitted multiple Maydays
FF searched and found door to South stairwell and placed axe in door
FF returned and retrieved victim who had vomited in mask and removed it
FF collapsed at top of stairwell and both fell down the stairwell
FF were found due to victims PASS device in the third floor stairwell
13.
Untitled Slide
14.
CONTRIBUTING FACTORS
Arson
Lack of auto fire suppression system
High-rise SOP's not followed
Air management doctrine not followed
Reverse stack effect in stairwell
15.
KEY RECOMENDATIONS
Ensure existing SOP's for high-rise ops are reviewed & enforced
Ensure a deployment strategy for high-risk incidents is developed
Ensure the IC develops an IAC, which is communicated to all FF's
Ensure the IC utilizes division/group supervisors
Ensure that FF's are properly trained in air management
16.
KEY RECOMMENDATIONS
Ensure FF's are properly trained in out-of-air SCBA emergencies
Ensure that IC is provided a chief's aide to assist in incident management
Ensure that IC establishes a stationary command post for incident management
Ensure that FF's are properly trained in Mayday SOP's and survival techniques
17.
DEDICATION
RENAMED ON AUGUST 15, 2012
18.
THOUSANDS WERE IN ATTENDANCE...
19.
REFERENCES
www.cdc.gov
(NIOSH)
www.firehouse.com
www.honoringheroes.com